The BI has numerous centrifuges to concentrate and separate a variety of samples with varying speeds.

Various Quick Spin microcentrifuges

Spin up to 8 x 1.5/2mL samples (fixed rotor).

Maximum rotor speed: 6 000 rpm (2 000 RCF).
Sample: 1.5 mL or 2 mL microfuge tubes.

Thermo Fisher Sorvall Legend Micro 21 Microcentrifuge

Spin up to 24 x 1.5/2mL samples (fixed rotor).

Suitable for biological samples, when using the rotor with the ClickSeal Biocontainment Lid.

Maximum rotor speed: 14,800 rpm (21 100 RCF).
Sample: 1.5 mL or 2 mL microfuge tubes.

Thermo Fisher Sorvall Legend Micro 21R Microcentrifuge

Spin up to 24 samples (fixed rotor) with refrigeration control.

Suitable for biological samples, when using the rotor with the ClickSeal Biocontainment Lid.

Maximum rotor speed: 14,800 rpm (21 100 RCF).
Sample: 1.5 mL or 2 mL microfuge tubes.

Thermo Fisher Sorvall Benchtop ST8R

Spin microfuge tubes, centrifugal tubes or plates with refrigeration control. Rotors are fixed or swinging, depending on the sample size.

Suitable for biological samples, when using the rotors with the appropriate ClickSeal Biocontainment Lid.

Rotor 24 x 1.5/2mL TX-150 with
round buckets
M10 rotor with microplate buckets
Speed 12 900 RPM
18 233 RCF
4 500 RPM
3 260 RCF
4 400 RPM
2 576 RCF
Samples 1.5 mL or 2 mL microfuge tubes 8 x 15 mL tubes 4 x 15 mL tubes 2 x micro-well plates
Thermo Fisher Sorvall Benchtop ST40R

Spin microfuge tubes, centrifugal tubes or plates with refrigeration control. Rotors are fixed or swinging, depending on the sample size.

Suitable for biological samples, when using the TX-750 rotor with the round buckets and the appropriate ClickSeal Biocontainment Lid.

Rotor 48 x 1.5/2mL TX-750 with
round buckets
TX-750 with
microwell buckets
Speed 15 200 RPM
25 055 RCF
4 700 RPM
4 816 RCF
Samples 1.5 mL or 2 mL microfuge tubes 56 x 15 mL tubes 28 x 15 mL tubes 4 x micro-well plates
Thermo Scientific Savant DNA SpeedVac (Concentrator)

Spin and concentrate samples by evaporating unwanted solvents when combining speed, vacuum and heat. Typical applications include concentrating DNA/RNA from low volume buffers or ethanol/isopropanol-water solutions.

Model: DNA120-115
Maximum rotor speed: 1 725 RPM (300 RCF).
Sample: 36 x 1.5 mL microfuge tubes.
Temperature control: ambient (low), 43oC (medium), 65oC (high).

Ultracentrifuges Thermo Fisher Ultracentrifuge WX90

Spin various sample volumes with refrigeration control at ultra-high speeds (>37 000 RPM or >200 000 RCF). Rotors are fixed or swinging, depending on the sample size.

Find more information here.

If you aren’t sure which centrifuge to use, refer to our comparison chart:

BI Centrifuge Comparison Chart

Some centrifuges are also located within CL-2 labs to support cell culture activites.

Instrument
Uses

  • Concentrating
  • Separating

Sample
Requirements

  • Liquids
  • Sample amounts must be within the weight range of rotors

System
Requirements

  • Non volatile substances